APC BR1500LCD 1500VA 865 Watts BACK-UPS RS | Model: BR1500LCDSKU: BR1500LCDStore ID: AS579080 |
APC BR1500LCD BACK-UPS RS. Output Power Capacity: 865 Watts/1500 VA. Nominal Input Voltage: 120V. Surge energy rating: 340 Joules. APC BR1500LCD 1500VA 865 Watts BACK-UPS RS BR1500LCD Features- Battery failure notification - Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Battery-protected and surge-only outlets - Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
- Cold-start capable - Provides temporary battery power when the utility power is out.
- Hot-swappable batteries - Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Disconnected battery notification - Warns when a battery is not available to provide backup power.
- Dataline Surge Protection - Provides protection of connected equipment from power surges on the data lines.
- Boost Automatic Voltage Regulation (AVR) - Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
- Automatic self-test - Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Adjustable voltage-transfer points - Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Adjustable voltage sensitivity - Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Audible alarms - Provides notification of changing utility power and UPS conditions.
- User-replaceable batteries - Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- USB connectivity - Provides management of the UPS via a USB port (not available on all models).
- Transformer-block spaced outlets - Protect equipment with input transformer blocks without blocking access to other receptacles.
- Intelligent battery management - Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Safety-agency approved - Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Lifetime data recovery warranty - Provides peace of mind by providing professional data recovery services in the event data is lost due to the failure of the unit.
- Adjustable voltage sensitivity - Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.
- Battery replacement without tools - Allows quick, easy battery replacement.
- LCD graphics display - Text and mimic diagrams that display modes of operation, system parameters and alarms.
Back-UPS RS Features & BenefitsProtection- Battery-protected and surge-only outlets - Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
- Safety-agency approved - Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Power conditioning - Protects connected loads from surges, spikes, lightning, and other power disturbances.
Convenience- Audible alarms - Provides notification of changing utility power and UPS conditions.
- Automatic restart of loads after UPS shutdown - Automatically starts up the connected equipment upon the return of utility power.
- Automatic self-test - Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Battery replacement without tools - Allows quick, easy battery replacement.
- LED status indicators - Quickly understand unit and power status with visual indicators.
- Cold-start capable - Provides temporary battery power when the utility power is out.
- Hot-swappable batteries - Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Resettable circuit breakers - Enables a quick recovery from overload events.
- Transformer-block spaced outlets - Protect equipment with input transformer blocks without blocking access to other receptacles.
- User-replaceable batteries - Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Manageability- Adjustable voltage sensitivity - Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Adjustable voltage-transfer points - Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Intelligent battery management - Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.
APC BR1500LCD 1500VA 865 Watts BACK-UPS RS| General | | Brand | APC |
|---|
| Model | BR1500LCD |
|---|
| Highlights | APC BR1500LCD BACK-UPS RS. Output Power Capacity: 865 Watts/1500 VA. Nominal Input Voltage: 120V. Surge energy rating: 340 Joules. |
|---|
| Output | | Output Power Capacity | 865 Watts/1500 VA |
|---|
| Max Configurable Power | 865 Watts/1500 VA |
|---|
| Nominal Output Voltage | 120V |
|---|
| Output Frequency (sync to mains) | 60 Hz |
|---|
| Crest Factor | 3 : 1 |
|---|
| Output Connections | (2) NEMA 5-15R (Surge Protection) (6) NEMA 5-15R (Battery Backup) |
|---|
| Waveform Type | Stepped approximation to a sinewave |
|---|
| Input | | Nominal Input Voltage | 120V |
|---|
| Input Frequency | 60 Hz +/- 3 Hz |
|---|
| Input Connections | NEMA 5-15P |
|---|
| Cord Length | 6 feet (1.83 meters) |
|---|
| Input voltage range for main operations | 88 - 139V |
|---|
| Input voltage adjustable range for mains operation | 78 - 152V |
|---|
| Maximum Input Current | 12A |
|---|
| Input Breaker Capacity | 15A |
|---|
| Batteries & Runtime | | Battery Type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
|---|
| Typical recharge time | 16 hour(s) |
|---|
| NRBC Quantity | 1 |
|---|
| Communications & Management | | Control panel | Multi-function LCD status and control console |
|---|
| Audible Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
|---|
| Surge Protection and Filtering | | Surge energy rating | 340 Joules |
|---|
| Filtering | Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 |
|---|
| Data Line Protection | RJ-45 Modem/Fax/DSL/10-100 Base-T protection,Co-axial Video / Cable protection |
|---|
| Physical | | Maximum Height | 8.75 inches (222 mm) |
|---|
| Maximum Width | 5.25 inches (133 mm) |
|---|
| Maximum Depth | 14.00 inches (356 mm) |
|---|
| Net Weight | 30.70 lbs. (13.95 kg) |
|---|
| Shipping Weight | 34.22 lbs. (15.55 kg) |
|---|
| Shipping Height | 12.00 inches (305 mm) |
|---|
| Shipping Width | 9.75 inches (248 mm) |
|---|
| Shipping Depth | 18.00 inches (457 mm) |
|---|
| Master Carton Units | 1.00 |
|---|
| Master Carton Weight | 34.22 lbs. (15.55 kg) |
|---|
| Environmental | | Operating Environment | 32 - 104 °F (0 - 40 °C) |
|---|
| Operating Relative Humidity | 0 - 95% |
|---|
| Operating Elevation | 0-10000 feet (0-3000 meters) |
|---|
| Storage Temperature | 23 - 113 °F (-5 - 45 °C) |
|---|
| Storage Relative Humidity | 0 - 95% |
|---|
| Storage Elevation | 0-50000 feet (0-15000 meters) |
|---|
| Audible noise at 1 meter from surface of unit | 45.00 dBA |
|---|
| Conformance | | Regulatory Approvals | FCC Part 15 Class B,FCC Part 68,NOM,TUV |
|---|
| Standard Warranty | 3 years repair or replace |
|---|
| Equipment protection policy | Lifetime : $150000 |
|---|
| Environmental Compliance | RoHS |
|---|
|